Micomme Product Non-invasive Ventilator ST-30K
Description
Non-invasive ventilation (NIV) refers to the provision of ventilatory support through the patient’s upper airway using a mask or similar device.
Non-invasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.
Application
Acute respiratory distress syndrome (ARDS) is characterised by acute onset respiratory failure, diffuse pulmonary opacities and severe hypoxemia. The use of NIV can help to avoid such complications such as a higher incidence of ventilator-associated pneumonia and barotrauma.
The patients with known or suspected COVID-19 with respiratory failure should be intubated and ventilated early in the disease course without the option for less invasive treatments, including non-invasive ventilation (NIV).
Advantage
6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.
The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.
Specification
Parameter |
ST-30K |
Ventilation mode |
S/T, CPAP, S, T, PC, VAT, HFNC |
Oxygen concentration |
21%~100%, (increment by 1%) |
Screen size |
5.7 Inch color screen |
Waveform display |
Pressure/flow |
IPAP |
4~40cm H2O |
EPAP |
4~25cm H2O |
CPAP |
4~20cm H2O |
Target tidal volume |
20~2500mL |
Backup BPM |
1~60BPM |
Backup time |
0.2~4.0S |
Rise time |
1~6 level |
Ramp time |
0~60min |
Ramp pressure |
CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O |
Pressure relief |
1~3 level |
Spontaneous Timin |
0.2~4.0S |
Spontaneous Timax |
0.2~4.0S |
I-Trigger setting |
Auto, 1~3 level |
E-Trigger setting |
Auto, 1~3 level |
Trigger lock |
Off, 0.3~1.5S |
Flow of HFNC mode |
10~70L/min |
Max flow |
300L/min |
Max leak compensation |
120L/min |
Method of pressure measure |
The pressure testing tube is on mask side |
Alarms |
Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted |
Apnea alarm range setting |
0S, 10S, 20S, 30S |
Disconnection alarm range setting |
0S, 15S, 60S |
Real-time monitoring data |
Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method |
Other settings |
Screen lock|Display brightness| Flow| Pressure| Waveform| Event summary |
Backup battery |
8 hours |