i Series Non-invasive ventilator (Sleep Apnea Treatment)
AST (Automatic Synchronization Technology)
Automatically follow the patient's breathing, accurately determine the time of patient trigger and replacement, and provide the corresponding inspiratory and expiratory pressure; automatic sensitivity technology without manually setting the sensitivity, minimize the patient's breathing work.

Automatic voltage regulation technology
Brand new scientific algorithm, automatically adjust the pressure, detect and respond to various respiratory events
Automatic pressure regulation technology can automatically and accurately monitor and identify 6 types of respiratory events such as hypopnea, obstructive apnea, airflow limitation, continuous snoring, massive leaks and central apnea respond to the first four categories in an instant. Such as Low ventilation, obstructive apnea, restricted airflow, continuous snoring.
COMF pressure release technology
Powerful pressure relief technology-COMF, is our own patent.
It could ensure the comfort level, high compliance, free from burdened breath nursing through the clinical test and demonstration.
Auto CPAP mode
According to the airway obstruction, the variable optimal positive airway pressure is automatically provided between the lowest IPAP and the highest IPAP, opening the airway while improving patient comfort.
Auto Bi-level mode
According to the airway obstruction, it automatically provides variable optimal bi-level pressure within the range of IPAP and EPA, opening the airway while improving patient comfort.
CPAP mode
The ventilator provides the same pressure in both the inspiratory phase and the expiratory phase, helping the patient to open the airway.
Bi-Level mode
IPAP and EPAP can be set separately and provide two-way pressure to help patients open the airway and breathe smoothly.
Parameters
Model |
C1 |
C2 |
C3 |
C5 |
B1 |
B5 |
Model |
CPAP |
CPAP |
Auto CPAP |
CPAP,Auto CPAP |
CPAP,Auto Bilevel |
CPAP,Auto CPAP,Bilevel,Auto Bilevel |
Pressure range |
4-20cm H2O |
4-20cm H2O |
4-20cm H2O |
4-20cm H2O |
4-25cm H2O |
4-30cm H2O |
Pressure accuracy |
±0.2cm H2O |
|||||
Max.Operation pressure |
30cm H2O |
|||||
Ramp time |
0 to 45 min(5-minute increments) |
|||||
COMF pressure relief |
\ |
1-3 level | ||||
Humidification level |
\ |
1-5 levels(113 to 185℉23 to 85 ℃) |
||||
Rise time |
\ |
\ |
\ |
\ |
1-4 levels |
1-4 levels |
Split night |
\ |
\ |
\ |
\ |
YES |
YES |
Data storage capacity |
8G USB disk |
|||||
Weight |
1.72kg |
|||||
Mean sound level |
≤30dB |