banner112

product

i Series Non-invasive ventilator (Sleep Apnea Treatment)

Short Description:


product detail imgs

Product Detail

i series OSA_PDF(1)-1 i series OSA_PDF(1)-2

AST (Automatic Synchronization Technology)

Automatically follow the patient's breathing, accurately determine the time of patient trigger and replacement, and provide the corresponding inspiratory and expiratory pressure; automatic sensitivity technology without manually setting the sensitivity, minimize the patient's breathing work.

AST

Automatic voltage regulation technology
Brand new scientific algorithm, automatically adjust the pressure, detect and respond to various respiratory events
Automatic pressure regulation technology can automatically and accurately monitor and identify 6 types of respiratory events such as hypopnea, obstructive apnea, airflow limitation, continuous snoring, massive leaks and central apnea respond to the first four categories in an instant. Such as Low ventilation, obstructive apnea, restricted airflow, continuous snoring.

COMF pressure release technology

Powerful pressure relief technology-COMF, is our own patent.
It could ensure the comfort level, high compliance, free from burdened breath nursing through the clinical test and demonstration.

Auto CPAP mode

According to the airway obstruction, the variable optimal positive airway pressure is automatically provided between the lowest IPAP and the highest IPAP, opening the airway while improving patient comfort.

Auto Bi-level mode

According to the airway obstruction, it automatically provides variable optimal bi-level pressure within the range of IPAP and EPA, opening the airway while improving patient comfort.

CPAP mode

The ventilator provides the same pressure in both the inspiratory phase and the expiratory phase, helping the patient to open the airway.

Bi-Level mode

IPAP and EPAP can be set separately and provide two-way pressure to help patients open the airway and breathe smoothly.

Parameters

Model

C1

C2

C3

C5

B1

B5

Model

CPAP

CPAP

Auto CPAP

CPAP,Auto CPAP

CPAP,Auto Bilevel

CPAP,Auto CPAP,Bilevel,Auto Bilevel

             

Pressure range

4-20cm H2O

4-20cm H2O

4-20cm H2O

4-20cm H2O

4-25cm H2O

4-30cm H2O

             

Pressure accuracy

±0.2cm H2O

   

Max.Operation pressure

30cm H2O

   

Ramp time

0 to 45 min(5-minute increments)

   

COMF pressure relief

                              1-3 level
     

Humidification level

1-5 levels(113 to 185℉23 to 85 ℃)

     

Rise time

1-4 levels

1-4 levels

             

Split night

YES

YES

             

Data storage capacity

8G USB disk

   

Weight

1.72kg

   

Mean sound level

≤30dB