Massive Selection for Parapac Ventilator - OH-70C High Flow Nasal Cannula Oxygen Therapy Device(HFNC) – Micomme
Massive Selection for Parapac Ventilator - OH-70C High Flow Nasal Cannula Oxygen Therapy Device(HFNC) – Micomme Detail:
- Automatic O2 concentration control technology
- Intelligent temperature and humidity control system
- Up to 70L/min high flow output
- Safe airway design to prevent cross-infection
Sepray OH-70C
Sepray high flow non-invasive breathing humidification treatment instrument through high flow, precise oxygen concentration and humidified air-oxygen mixed gas, effective respiratory treatment for patients, Sepray OH-70C can effectively improve patient oxygen Level, and maintain the normal operation of airway mucus cilia.
Applied departments:
ICU, Respiratory dept. Emergency dept. Neurosurgery dept. Geriatrics dept.Cardiolology dept.
Clinical Treatment Characteristics
- Timely and effective improvement of oxygenation level
- Scour anatomical dead space and reduce carbon dioxide re-inhalation
- Form a certain positive airway pressure, keep the airway open, reduce breathing work
- Fully humidified and warmed, the airway mucus cilia are in the best condition
- Comfortable user experience and improved compliance
Clinical Application
Mild to moderate acute respiratory
Respiratory distress syndrome
Sequential treatment after extubation
Cardiogenic pulmonary edema
Cardiothoracic surgery
Assisted endoscopy
Pulmonary fibrosis
Palliative treatment
Various sputum production disorders
Comfort
- Fully humidified gas and suitable temperature
- Comfortable treatment for patients
Special silicone nasal congestion
- High compliance without oppressive feelings
Provide different sizes of nasal congestion
- Adapt to different patients to meet clinical needs
Easy to use
-Innovative safe airway design, the host without having to disinfect
Efficiency
- 21%-100% O2 concentration adjustable with 1% adjusting precision
- Automatic 02 concentration control technology, No need for external manual adjustment, oxygen concentration control is more precise
- When the flow rate changes, the air oxygen mixer automatically adjusts to ensure the stability of the oxygen concentration output
- Built-in O2 blender and concentration monitoring module
- Providing air with core body temperature and 100% relative humidity
- Adjustable temperature from 31℃ to 37℃
Parameters Sheet
Parameters |
OH-70C |
Oxygen concentration |
21%-100% |
Flow settings |
High Mode:2L/min- 25L/min Low Mode:10L/min-70L/min |
Temperature |
31℃-37℃ |
Timing function |
Yes |
Precise adjustment of oxygen concentration |
Automatic O2 concentration control |
Trend review |
1 days, 3 days, 7days |
Real time monitoring parameter |
Flow,Temperature,O2 concentration, Treatment time |
Treatment interfaces |
Children nasal cannula, Nasal cannula, Tracheostomy, Face mask |
Dimensions |
340*228*162mm |
Weight |
3.3kg |
Product detail pictures:
Related Product Guide:
We often persist with the theory "Quality To start with, Prestige Supreme". We are fully committed to delivering our clientele with competitively priced good quality items, prompt delivery and experienced support for Massive Selection for Parapac Ventilator - OH-70C High Flow Nasal Cannula Oxygen Therapy Device(HFNC) – Micomme , The product will supply to all over the world, such as: Florida, Croatia, Uruguay, Really should any of these items be of interest to you, please let us know. We will be pleased to give you a quotation upon receipt of one's detailed specifications. We've our personal specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
By Lilith from Nepal - 2017.10.27 12:12
The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
By Sophia from Accra - 2018.02.04 14:13