banner112

product

Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme

Short Description:


product detail imgs

Product Detail

We attempt for excellence, company the customers", hopes to be the top cooperation team and dominator company for personnel, suppliers and customers, realizes price share and continual marketing for Flying With Sleep Apnea , Non Invasive Bipap , Cpap Machine With Humidifier , Presently, we're wanting forward to even higher cooperation with abroad shoppers depending on mutual rewards. You should really feel totally free to make contact with us for more aspects.
Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme Detail:

High performance Non-invasive Ventilation Solution

Accurate oxygen concentration

Premium automatic synchronization technology, excellent man-machine synchronization

1.Ventilation modes

st1

Volume Assured Technology(VAT)

Automatically estimates the pressure need to fit target tidal volume according to patient’s change and provides incrementally IPAP and EPAP.

 Applied departments:

ICU, Respiratory dept. Emergency dept. Neurosurgery dept. Geriatrics dept.Cardiolology dept.

 Easy to use

-Battery with 8 hours life

5.7 inch colorful LCD screen

One button control

 Integrated trolly

The trolly can be equipped with a ventilator,battery,humidifier, boom, oxygen cylinder, tubing and mask at the same time, and the whole set of treatment equipment can be moved with one hand.

 Effective

Premium Automatic Synchronization Technology

Excellent man-machine synchronization

The device triggers inhalation based on flow and volume, so can judge the trigger timing according to the patient’s inhalation effort.

The trigger has 3 grades, and can satisfy patients who need the particularly sensory threshold

The device can automatically adapt the algorithm logic to disease status and wearing conditions. Even in high frequency respiration or leakage changing, also keep the pressure accurate and stable.

 Accurate Oxygen concentration control Better oxygenation

High-quality improvement of the blood oxygen saturation by the accurate and stable calculating and adjusting oxygen concentration

Connect with central oxygen supply system directly, and

can work without extra oxygen flow indicator .

Real-monitoring the oxygen concentration. The alarm is triggered by the abnormal oxygen concentration for the oxygen therapy safety.

Parameters of ST-30H

Parameters Description
Ventilation mode S/T,CPAP,S,T,PC,VAT
Oxygen concentration 21%-100%
Screen size 5.7 inches color screen
Waveform Pressure/flow
IPAP 4-30cmH2O
EPAP 4-25cmH2O
CPAP 4-20cmH2O
Target tidal volume 25ml-2500ml
Backup BPM 1-60BPM
Backup Ti 0.2s-4.0s
Rise time 1-6 Levels
Ramp time 0-60min(One unit per minute)
Ramp pressure CPAP mode:4cmH2O-CPAP;Other mode:4-25cmH20
Pressure relief 1-3 Levels
Spontaneous Timin 0.2-4.0S
Spontaneous Timax 0.2-4.0S
I-Trigger setting Auto,1-3 Levels
E-Trigger setting Auto,1-3 Levels
Trigger lock Off,0.3-1.5S
Method of measure pressure The pressure sensor of oxygen tube on mask side
Real-time monitoring data Oxygen concentration/Oxygen Source pressure/Pressure/Ventilation Per Min/Breath rate/Current leakage/Trigger method
Alarms Apnea/Disconnection/Low minute volume/Low tidal volume/Power off/Over high pressure
Backup battery Removable backup battery(Standby 8 hours
Weight Main devive:2.9kg Battery:2.6kg
Dimensions(LWH) 24.3×16.7x13cm
AC voltage 110-240VAC
Electrical requirements 110-240VAC,50/60Hz

Humidifier parameters

Heating range 40-70℃
Adjustment 1-9 Levels

 


Product detail pictures:

Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme detail pictures

Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme detail pictures

Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme detail pictures

Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme detail pictures


Related Product Guide:

Adhering into the basic principle of "quality, assistance, effectiveness and growth", we have attained trusts and praises from domestic and worldwide client for Good User Reputation for Infant High Flow Nasal Cannula - ST-30H Non-invasive ventilator – Micomme , The product will supply to all over the world, such as: Canada, Seattle, Barbados, As an experienced manufacturer we also accept customized order and we could make it the same as your picture or sample specification. The main goal of our company is to live a satisfactory memory to all the customers, and establish a long term business relationship with buyers and users all over the world.
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Anne from Libya - 2017.01.11 17:15
    The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Iris from Kenya - 2017.04.08 14:55
    Write your message here and send it to us