User-friendly high flow nasal cannula device 70C

Short Description:

User-friendly design: automatic water-adding function to save manual operation.


product detail imgs

Product Detail

1代高流量1

 

 

OH-70C High Flow Nasal Cannula Oxygen Therapy Device(HFNC)1

Description

HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.

Humidified high flow nasal cannula therapy is a form of non-invasive respiratory support which has been compared to continuous positive airway pressure (CPAP).

 

Application

When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution! 

The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.

 

Advantage

In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.

In 2020, micomme ranked the sixth in export of medical respiratory devices in China.

Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration.

Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 Intelligent water-controlling system, automatically maintaining the optimal water level in the water chamber.

 

Specification 

Model

OH-70C

Oxygen Adjustment

Setting

Automatic

 

Range

21%-100%

 

Flow

Low flow mode

2-25L/min

 

High flow mode

10-70L/min

Temperature settings

31℃-37℃

Real time monitoring parameters

Flow, FiO2, Temperature, Treatment time

 

 

 

Data

Trend review

1、3、7 days review

 

Content of review

Flow, FiO2, Temperature, Treatment time

 

Presetting of treatment time

Yes

 

 

Management

Auto reminder of maintenance

Yes

 

Main device disinfection

No need disinfection for circuits system

Wipe disinfection for device surface

Screen

4.3 inches

Dimension

340*228*162mm

Weight

3.3kg

 

 

 

Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 