banner112

product

Sepray Series 1-6 Levels Rise Time Home Care Ventilator For COPD ST-30D

Short Description:

360° anti-back flow patent water chamber which can prevent the water in the chamber from returning to main machine when the water is below the highest level.
Unique anti dry burning technology, when the temperature is higher than the limiting temperature, the device will automatically stop heating.


product detail imgs

Product Detail

ST-30D backST-30D detailST-30D left side

Description

Home Non-invasive ventilation (NIV) with bi-level positive airway pressure (BiPAP) is commonly used to treat patients admitted to hospital with acute hypercapnic respiratory failure (AHRF) secondary to an acute exacerbation of chronic obstructive pulmonary disease (AECOPD).

Home Non-invasive ventilation at home improves survival and decreases healthcare utilization in medicare beneficiaries with Chronic Obstructive Pulmonary Disease with chronic respiratory failure which can reduce mortality and the number of repeat respiratory failure and readmissions by continuing the acute noninvasive ventilatory therapy as a long-term therapy.

 

Application

Chronic Obstructive Pulmonary Disease, it is a type of obstructive lung disease characterized by long-term breathing problems and poor airflow. The main symptoms include shortness of breath and cough with sputum production. COPD is a progressive disease, meaning it typically worsens over time.

Emphysema is a lung condition that causes shortness of breath. In people with emphysema, the air sacs in the lungs (alveoli) are damaged. Over time, the inner walls of the air sacs weaken and rupture — creating larger air spaces instead of many small ones.

 

Advantage

360° anti-back flow patent water chamber which can prevent the water in the chamber from returning to main machine when the water is below the highest level.

Unique anti dry burning technology, when the temperature is higher than the limiting temperature, the device will automatically stop heating.

Intelligent and safe, it can automatically control the temperature of the heater below 80 ℃.

13 intelligent alarm modules, including 13 abnormal alarms and low tidal volume alarm, ensure the safety of patients.

 

Specifications

Description ST-30D
Mode CPAP S, S/T

Pressure range

(cmH2O)

IPAP:4-30

EPAP:4-25

CPAP:4-20

Rise time 1-6 levels
Backup Rate (BPM) 5-30

COMF

pressure relief

1-3 levels
Humidification 1-5 levels (113 to 185°F/45 to 85°C)
Ramp time 0 to 45 min (5-minute increments)

Data storage

capacity

>1 year, Micro SD Card 4G

Dimensions

(L x W x H)

24.5×16×10.5 cm
Weight 1.75 kg
Mean sound level ≤28 dB
Write your message here and send it to us