70L Per Minute High Flow Nasal Cannula Equipment Non Invasive 70B
Description High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute. High Flow Nasal Cannula (HFNC), isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’...
inquiry
detail
User-friendly high flow 60A
Description HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort. High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute. Application When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. ...
inquiry
detail
User Friendly 70L/Min High Flow Oxygen Therapy Machine 70B
Description A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula. HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting. Application HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure....
inquiry
detail
Micomme Non-invasive Ventilator ST-30H
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
inquiry
detail
Micomme Product Non-invasive Ventilator ST-30K
Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections.
inquiry
detail
Hospital Non-invasive ventilator ST-30K
Better chance of survival: NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.
inquiry
detail
Non-invasive ventilator ST-30H for hospital use
Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.
inquiry
detail
ST-30K Non-invasive Ventilator
Multi-function knob design make it easy to set the parameters; Humanized 17 degree elevation design brings great reading experience; 8 hours back-up battery.
inquiry
detail
Micomme Product ST-30K for hospital use
5.7-inch LCD color screen, flow rate and pressure double waveform, setting, alarm, treatment information displayed on the screen, combined with a knob. A single page can complete all settings. Parameters setting and real-time treatment data display on the same screen, convenient to adjust the parameters according to patients’ conditions.
inquiry
detail
Micomme Product ST-30K with Non-invasive Ventilation Solution
Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
inquiry
detail
Micomme Non-invasive Ventilator ST-30K with HFNC Solution
Ventilation mode S/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
inquiry
detail
Micomme High Performance Non-invasive Ventilator ST-30H
Max flow 210L/min
Max leak compensation 90L/min
Method of pressure measure The pressure testing tube is on mask side
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
inquiry
detail
<<