banner112

product

70L Per Minute High Flow Nasal Cannula Equipment Non Invasive 70B

Short Description:


product detail imgs

Product Detail

通用图1带台车 通用图通用图2

Description

High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.

 High Flow Nasal Cannula (HFNC), isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.

 

 Application

Acute hypoxic respiratory failure (ARF) was the first condition treated with HFNC in adults. The use of heated and humidified high flow nasal cannula (HFNC) has become increasingly popular in the treatment of patients with acute respiratory failure through all age groups.

 Other applications of HFNC include the prevention of postextubation hypoxaemia, pre-oxygenation before sedation/anaesthesia and oxygenation during bronchoscopy.

 

 Advantage

In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.

 At present, micomme occupies over 50% market share in high flow filed in China.

 Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 The machine uses timing function, which is convenient for nurses to charge by time.

 Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and Oconcentration.

 

Specifications

Parameters OH-70B
Oxygen Adjustment Setting Automatic
Oxygen Adjustment Range 21%- 100%
Low flow mode 2- 25L/min
High flow mode 10- 70L/min
Temperature settings 31℃, 34℃,37℃
Real time display parameters Preset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes
Auto reminder of maintenance Yes
Main device disinfection No need disinfection for circuits system
Wipe disinfection for device surface
Screen 4.3 inches
Dimension 340*228*162mm
Weight 3.3kg
Alarm Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 

 